Mansions Phase 1-LR 980511 (09) e.o.. E,~:,,~,~. I,~e. ~ ~'~4 G~dni~jh* Lane .Tgt. (g72) 241-451?.-``. RoneEn_qineers
Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-183 Date of Observation 4/28/98 Report Date 05/11/98
To Western Rim Services
Location BUILDING SLAB 6, NORTHEAST CORNER, 5' SOUTH, 5' WEST
Contractor
Supplier LATTIMORE Plant 7 I Truck 755 Ticket 7050193
Time Sampled 10:20 Time Batched 10:10 Weather Condition CLOUDY
Concrete Temperature (°F) 63 Ambient Temperature (°F) 70 Mix Number 51
Mix Description 3000PSI W/R Unit Weight Water Added 20 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
Concrete Cylinder Test(s)
I IT°tal L°ad C°mpressive
Specimen Age Test Date
No, (Days) (lbs.) Strength (psi) Strength Required {psi)
93A 7 5/05 78000 2760 3000/28 DAYS
B 28 5/26
C 28 5/26
D H
Curing Method Test Method Standard 6" x 12" Engineer/Technician D. GODBEY
ASTM C31 I ASTM C39 I Area 28.27 sq. in.
Signature: Mike Fuller, ~.Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality Icomposition, appearance, performance, etc,} or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reporl:s are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\repo~s\D7429-183-98\ST May 11. 1998