Mansions Phase 1-LR 980511 (10) Clone I~g(neers, inc. .' ~ +~'~4 ~oodnigh~ Lane : Tel. ~72~ 241-4517,-,,,
Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-184 Date of Observation 4/28/98 Report Date 05/11/98
To Western Rim Services
Location PAVING NEXT TO BUILDING 38, SOUTHWEST CORNER, 10' EAST 5' SOUTH
Contractor
Supplier LATTIMORE IPiant6 ITruck452 Ticket 6070799
Time Sampled 11:30 Time Batched 11:20 Weather Condition CLOUDY
Concrete Temperature (°F) 63 Ambient Temperature (°F) 70 Mix Number 36
Mix Description 4.50 SACKS W/R AiR Unit Weight Water Added 15 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4 1/2
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
1 5A 7 5/05 60000 21 20 3000/28 DAYS
B 28 5/26
C 28 5/26
D H
Curing Method Test Method I Standard 6" x 12" Engineer/Technician D. GODBEY
ASTM C 31 ASTM C 39I Area 28.27 sq. in.
Mike Fuller, ~ Supervisor, CMT
Signature:
Remarks and/or Distribution
Distribution:
(1) Mr, Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D, Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:.,wpwin~.repor~s\D7429-184-98\$T May 11. 1998