Mansions Phase 1-LR 980511 (11) Rone Engineers, inc. ~"~'~, ~oodnight Lnne Te{. (g72J 241-4F~
Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-191 Date of Observation 4/29/98 Report Date 05/11/98
To Western Rim Services
Location PAVING BEHIND BUILDING 10, NORTHEAST CORNER, 5" WEST, 5" NORTH
Contractor
Supplier LATTIMORE I Plant 6 I Truck 802 Ticket 6070892
I
I
Time Sampled 12:10 Time Batched 12:00 Weather Condition CLEAR
Concrete Temperature (°F) 67 Ambient Temperature (°F) Mix Number 61
Mix Description 3000 PSI WIR AIR Unit Weight Water Added 35 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 8.0
Concrete Cylinder Test(s)
I IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
97A 7 5/06 52000 1840 3000/28 DAYS
B 28 5/27
C 28 5/27
D H
CuringMeth°d I TestMeth°d__ Standard 6" x12" I Engineer/'FechnicianD'GODBEY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, ~,~upervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C, D, Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports;D7429-191-98\ST May 11, 1998