Mansions Phase 1-LR 980508 (2) Rone Engineers, Inc. 1 ~'~4 Goocln,ght Lane Tel. (972) 241-451'~' RoneEnQine
: ers
'. Metro (972) 263-1555
Dal~as..-For~ Worth Dallas. Texas ~
75229 i Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-116 Date of Observation 3/26/98 Report Date 05/08/98
To Western Rim Services
Location BUILDING //4, NORTHEAST END, 10' WEST, 50' SOUTH
Contractor
Supplier LATTIMORE I Plant 6 Truck 757 Ticket 6068910
I
Time Sampled 9:10 Time Batched 9:00 Weather Condition CLOUDY
Concrete Temperature (°F) 76 Ambient Temperature (°F) 79 Mix Number 14
Mix Description 5.50 SACKS W/R Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
Concrete Cylinder Test(s)
I IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
64A 7 4/02 89000 3150 3000/28 DAYS
B 28 4/23 116000 4100
C 28 4/23 123000 4350
D H
Curing Method Test Method Standard 6" x 12" I Engineer/Technician D. GODBEY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
I
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.