Mansions Phase 1-LR 980508 (5) Pone Engineers. Inc. 1~'~34 Goodnight Lane Tel. (972) 241-45~'' RoneEn( ineers
Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-127 I Date of Observation 4/02/98 Report Date 05/08/98
To Western Rim Services
Location BUILDING //36, GRADE BEAMS
Contractor
Supplier LATTIMORE MATERIALS I Plant 7 ] Truck 611 Ticket 7049064
I
I
Time Sampled 10:45 Time Batched 9:50 Weather Condition PT CLOUDY
Concrete Temperature (°F) 72 Ambient Temperature (°F) 78 Mix Number 14
Mix Description 4.50 SACKS W/R Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.5
Concrete Cylinder Test(s)
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
71A 7 4/09 68000 2410 3000/28 DAYS
B 28 4/30 98000 3470
C 28 4/30 100000 3540
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports~D7429-127-98\ST May 8, 1998 ~