Mansions Phase 1-LR 980429 (03) Rone Englneers, Inc. 1-~'~34 Goodnight Lane TeL (972) 241-45''''~' RoneEn ine ers
Dallas,'Fo~ Wor~l~ Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-122 I Date of Observation 3/31/98 Report Date 04/29/98
I
To Western Rim Services
Location BUILDING #34 - NORTH 50' SOUTH, 3' EAST
Contractor
Supplier LATTIMORE I Plant7 I Truck 458 Ticket 7048908
Time Sampled 11:50 Time Batched 11:40 Weather Condition CLEAR
Concrete Temperature (°F) 70 Ambient Temperature (°F) 72 Mix Number 14
Mix Description 4.50 SACKS Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) --
ENTRAINED AIR (%) --
Concrete Cylinder Test(s)
Specimen Age Test Date
No, (Days) (lbs.) Strength (psi) Strength Required (psi)
67A 7 4/07 69500 2420 3000/28 DAYS
B 28 4/28 86000 3040
C 28 4/28 85500 3020
D H
Curing Method ] Test Method Standard 6" x 12" I Engineer/Technician D. GODBEY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
I
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition. appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive uae of the clients to whom they are
addressed.
c:'~wpwimreports~D7429-122-98\ST April 29. 1998