Loading...
Mansions Phase 1-LR 980429 (05) Rone Engineers, Inc. 1~'""4 Goodnight Lane I Tel. (972) 241-451 RoneEn ineers Dal~as.'Forl Worm I Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-171 Date of Observation 4/21/98 Report Date 04/29/98 To Western Rim Services Location 3' WEST, 2' SOUTH OFF NORTHEAST CORNER, BUILDING //8 SLAB Contractor Supplier LATTIMORE Plant 7 I Truck 451 Ticket 7049878 Time Sampled 6:15 Time Batched 5:45 Weather Condition CLEAR Concrete Temperature (°F) 64 Ambient Temperature (°F) 41 Mix Number 51 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.5 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 85A 7 4/28 86000 3040 3000/28 DAYS B 2_8 5/19 C 28 5/19 D H Curing Method Test Method I Standard 6" x 12" Engineer/Technician R. YARBROUGH ASTM C 31 ASTM C 39I Area 28.27 sq. in. Signature: Mike Fuller, Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E, Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr, Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other featbre of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-171-98\ST April 29, 1998