Loading...
Northlake 635(01)-CS 861105The City With A Beautiful Future P. O. Box 478 Coppell, Texas 75019 214 - 462 - 0022 November 5, 1986 Mr. James A. Koch, Jr. 3988 N. Central Expressway Suite #1130 Dallas, Texas 75204 RE: Northlake 635 Business Park Dear Jim: A Development Review Committee meeting was held on November 4, 1986 and the above mentioned project was also discussed. Per our meeting, please make indicated corrections and submit twenty-two (22) sets of Preliminary Plat, Preliminary Site Plan, and five (5) sets of Engineering Plans no later than 10:00 a.m. on November 10, 1986. If you have any questions, please give me a call. Sincerely, Shohre Daneshmand Civil Engineer cc: file SD/lsg PERS~ The City With A Beautiful u Wednesday, November 5, 1986 RE: Northlake 635 Business Park 1) Attach overall Drainage Area Map with the rest of Plans. 2) Maintenance Agreement - (Homeowners Agreement - Ex 3) No cushion sand allowed; 6" reinforced concrete wi1 stabilized subgrade. 4) Fire Lane turnaround radius. 5) Specify Utility Easement unless otherwise required 6) Off-site Drainage does not match. 7) Contours connected wrong. 8) On Final submittal of plans, need: a) Final Plat b) Final Site Plan c) Civil Engineering plans (approved); if any d) Cost estimate for all improvements (Developme~ with Director of Public Works. e) Streetscape and Maintenance Agreement for Lan{ attached Homeowners Agreement (Exhibit "A"). f) Landscaping Plan 9) Page Numbers. 10) Must show 12' X 30' Dedicated Loading Docks. 11) Does 8" water line provide adeaquate fire protecti~ flow rate). 12) Lot numbers and Block numbers. P. O. Box 478 Coppell, Texas 75019 214 - 462- 0O22 .~gineering ~ibit "A") . :h 6" lime by the City. Fees); check [scaping; see (check the Minutes of November 4, 1986 DEVELOPMENT REVIEW COMMITTEE The Development Review Committee met at 8:30 a.m. on 4, 1986 at the Coppell Town Center. The following memb~ Ed Powell, City Engineer Taryon Bowman, Sr. Planning Technician Shohre Daneshman, Civil Engineer Steve Morton, Chief Development Inspecto~ Troy Glidewell, Fire Marshal Dale Jackson, Building Official Steve Goram, Director of Public Works Linda Glidewell, Secretary Gabe Favre, Ginn, Inc. Richard Milner, Coppell Cablevision Jerry Davis, General Telephone Tim Branchau, Texas Power and Light Glen Fabian, Texas Power and Light Fred Harris, Lone Star Gas Doug Jones, Lone Star Gas The fni]ow~pg items were reviewed by the Committee: lesday, November rs were present: Northlake 635 Business Park - Preliminary Plat: COMMENTS: Gabe Favre - Ginn, Inc.: (1) Provide signature blocks for Planning and Zon: and City Council on preliminary plat. (2) Verify with City Engineer whether water mains, mains and storm drainage system needs to bi easement or not. (3) Verify with Fire Marshal that fire lane turnaz in lieu of cul-de-sac turnaround. (4) Parking requirements of proposed building aret What happens when future expansion is comple parking for new area be located? (5) Indicate pavement design (thickness, strength, (6) Use Technical paper 40, not TP-25 in design of Shohre Daneshmand - Engineering: (1) Grading plan and off site drainage do not mate (2) Contours are connected wrong. (3) Engineering plans - need cover sheet. (4) Need separate set of Civil Plans showing drai~ will be constructed. (5) Specify drive a~>proach. Tro~. Gild,well - Fire Marshal: (1) Fire lane turnaround radius. Dale Jackson - Building Official: (1) Must show they are dedicated loading docks (12 Steve Goram - Public Works: (1) Landscaping in R.O.W. -'provide maintenance a Ed Powell - City Engineer: (1) Check wtth Fire Marshal.- will 8" line provid protection? General Comments: (I) Must provide cost of total development for imp City R.O.W., dedicated easements parking lots. (2) All development fees must be paid before final submitted to the City council for eonsiderati ~ 0 fees will be computed by the D_rector ~rovide Landscape Mazntenance' (see attachec Agreement). Page 8 ng Commission sanitary sewer located within ~und can be used is 79 spaces. :ed? Where will etc.) on plans. storm sewer. age - how it x 30). ~ee~ent. adequate fire rovements within plat will be pn. Development