Mansions Phase 1-LR 980428 (4) non~ :ngineer~, Inc. ~ ~-'~4 Goodnight Lane Tel. (972)24~-45~,3'''-. RoneEn ine ers
Dallas;Eon Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-109 I Date of Observation 3/25/98 Report Date 04/28/98
I
To Western Rim Services
Locatiort BUILDING #42 - SOUTHWEST CORNER, 8' NORTH, 3' EAST
Contractor
Supplier LATTIMORE I Plant 3 Truck 735 Ticket 3059600
Time Sampled 4:30 Time Batched 4:40 Weather Condition CLOUDY
Concrete Temperature (°F) 67 Ambient Temperature (°F) 69 Mix Number 14
Mix Description 4.50 SACKS W/R Unit Weight Water Added 20 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
Concrete Cylinder Test(s)
I IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
60A 7 4/01 82500 2920 3000/28 DAYS
B 28 4/22 103000 3640
C 28 4/22 107000 3780
D H
Curing Method I Test Method Standard 6" x 12" I Engineer/Technician D. GODBEY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
I
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; Citv of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat resulta preaented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition, appearance, performance, etc.{ or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:',,wpwin\reports\D7429-109-98\ST April 28, 1998