Mansions Phase 1-LR 980427 (03) Rone Engineers, Inc. 1' t Goodnight Lane Tel. (972) 24~-451- RoneEnclineers Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansions By The Lake Purchase Order Number 3137-D7429-155 Date of Observation 4/14/98 Report Date 04/?7/98 To Western Rim Services Location BUILDING //35 FROM THE SOUTHWEST CORNER, 47' NORTH AND 2.5' EAST Contractor Supplier LATTIMORE Plant 6 I Truck $03 Ticket 6070027 I Time Sampled 8:30 Time Batched 8:20 Weather Condition CLEAR Concrete Temperature (°F) 79 Ambient Temperature (°F) 70 Mix Number 51 Mix Description W/R Unit Weight Water Added NONE Physical Data ACT UAL SPECIFICATIONS SLUMP (in.) 4 1/2 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 83A 7 4/21 79000 2790 3000/28 DAYS B 28 5/12 C 28 5/12 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell /4'4' (1) Mr. Mike Hodge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.l or an,/other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom the,/ are addressed. c:\wpwin\repor~s\D7429-155-98\ST April 27. 1998