Mansions Phase 1-LR 980427 (04) Rone Engineers, In(;. : 1 '~"~4 Goodnight Lane Tel. (972) 241-451-z.-.. ineers
Dallas/Fort Worth, Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-156 Date of Observation 4/14/98 Report Date 04./27198
To Western Rim Services
Location BUILDING #34 SLAB, NORTHEAST CORNER, 2.5' WEST, 3' SOUTH
Contractor
Supplier LATTIMORE [Plant7 ITruck457 Ticket 7049599
Time Sampled 11:00 Time Batched 10:50 Weather Condition CLEAR
Concrete Temperature (°F) 84 Ambient Temperature (°F) 70 Mix Number 51
Mix Description W/R Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.0
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
84A 7 4/21 81000 2870 3000/28 DAYS
B 28 5/12
C 28 5/12
D H
Curing Method I TestMethod Standard 6" x12" I Engineer/TechnicianD. GODBEY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reporl:s are for the exclusive use of the clients to whom they are
addressed.
c:~wpwin\reports',D7429-156-98~ST April 27, 1998