Mansions Phase 1-LR 980427 (14) Rone Engineers. Inc. 1 -*"~4 Goodnight Lane ,! Tel. (972) 241-451'~' RoneEn ineers
Dallas.-'Fort VVodh Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-142 Date of Observation 4/07/98 Report Date 04/27/98
To Western Rim Services
Location BUILDING 38, GRADE BEAMS
Contractor EDWARDS CONSTRUCTION
Supplier LATTIMORE Plant 7 I Truck 460 Ticket 7049283
I
Time Sampled 8:15 Time Batched 7:40 Weather Condition CLEAR
Concrete Temperature (°F) Ambient Temperature (°F) Mix Number 14
Mix Description 4.50 SACKS W/R Unit Weight Water Added 15 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7.75
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
78A 7 4/14 70000 2480 /28 DAYS
B 28 5/05
C 28
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hedge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports\D7429-142-98\ST April 27, 1998