Mansions Phase 1-LR 980425 (3) I
Oallas,~ron Wort~ Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansions By The Lake Purchase Order
Number 3137-D7429-151 [ Date of Observation 4/09/98 Report Date 04/25/98
To Western Rim Services
Location BUILDING #9 SLAB - SOUTHWEST CORNER, 15' EAST, 5' NORTH
Contractor
Supplier LATTIMORE Plant 7 [ Truck 574 Ticket 7049401
Time Sampled 8:10 Time Batched 8:00 Weather Condition CLEAR
Concrete Temperature (°F) 69 Ambient Temperature (°F) 72 Mix Number 61
Mix Description 5 SACKS W/R AIR Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5 1/2
Concrete Cylinder Test(s)
[ [ Total Load Compressive
Specimen Age Test Date
No, (Days) (lbs,) Strength (psi) Strength Required (psi)
81A 7 4/1 $ 93000 3290 3000/28 DAYS
B 28 5/07
C 28 5107
D H
Curing Method [ TestMethod I Standard 6" x12" I Engineer/TechnicianD-GODBEY
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, ~l~l Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Mike Hodge; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the cJients to whom they are
addressed.
c:\wpwin\reports\D7429-151-98\ST April 25. 1998