Loading...
Mansions Phase 1-LR 980422 (5) Rone Engineers, Inc. ~".34 Goodnight Lane Tel. (972) 241-4.r Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 1 OF 4 Report No: 3137-D7429-161A Sample Date: April 17, 1998 Client: Western Rim Services Report Date: April 22, 1998 Location: Building//41 Technician: Mike Fuller # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. ('Kips) Pressure Elongations End (i) End (2) Elongations Tolerance 1 B-29 NORTH SIDE 33K 2 1/8 2 1/$ YES 2 S-29 NORTH SIDE 33K 2 1/8 2 I/4 YES 3 S-48 NORTH SIDE 33K 3 5/$ 3 5/8 YES 4 B-30 NORTH SIDE 33K 2 2/8 2 5/8 YES 5 B-30 NORTH SIDE 33K 2 2/8 2 1/2 YES 6 B-30 NORTH SIDE 33K 2 2/8 2 1/2 YES 7 B-30 NORTH SIDE 33K 2 2/8 2 1/2 YES $ B-57 '~EST SIDE 33K 4 3/8 4 1/8 YES 9 S-57 ~ SIDE 33K 4 3/8 BROKEN CABLE 3 1/2 NO** 10 B-78 SOUTH SIDE 33K 6 5 1/2 YES 11 S-63 '*~'EST SIDE 33K 4 7/$ 5 YES 12 S-62 V~.ST SIDE 33K 4 3/4 5 YES 13 B-62 WEST SIDE 33K 4 3/4 5 YES 14 S-62 WEST SIDE 33K 4 3/4 5 YES 15 S-62 WEST SIDE 33K 4 3/4 5 YES 16 $-65 WEST SIDE 33K 5 5 1/8 YES 17 B-65 WEST SIDE 33K 5 5 1/4 YES Ig S-65 WEST SIDE 33K 5 5 YES 19 S-61 WEST SIDE 33K 4 5/8 6 + NO * ~quipm~nt ID: Ram No: Pump No: Gauge No: Equipment Calibration Date: Comments: *SHORT, + LONG, POSSIBLE UNDER PULL; **BROKEN CABLE Distribution: (1) Mr. Richard E. Simmons; We. stem Rim Services (I) Mr. Larry Davis; City of Coppell (1) Mr. Le~ Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leuers and reports are for the exclusive use of the clients to whom they arc addressed. ~ c :\wpwin\reports\D7429-161 A-98\ST Revised Aprll 22, 1998 p.o.Q ~_~mi~r~. I~e. 34 GoodnicJht Lane TeL (972} 241-4E Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 2 OF 4 Report No: 3137-D7429-161A Sample Date: April 17, 1998 Client: Western Rim Services Report Date: April 22, 1998 Location: Building #41 Technician: Mike Fuller # Tendon Location Jack Force Gauge Required Elongations Elongations Toufl Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 20 S-61 WF..ST SIDE 33K 4 518 5 YES 21 !t-64 WEST SIDE 33K 4 7/8 5 1/8 YES 22 S-64 WEST SIDE 33K 4 718 5 1/8 YES 23 S-64 WEST SIDE 33K 4 7/8 5 YES 24 S-62 WEST SIDE 33K 4 3/4 5 1/4 YES 25 S-64 WEST SIDE 33K 4 7/8 5 1/4 YES 26 B-64 WFz~T SIDE 33K 4 718 5 YES 27 S-62 WEST SIDE 33K 4 3/4 5 YES 28 S-62 WEST SIDE 33K 4 3/4 5 YES** 29 B-69 WF_.~T SIDE 33K 5 1/4 5 1/2 YES 30 S-69 WE. ST SIDE 33K 5 114 5 1/2 YES 31 S-69 W~ST SIDE 33K 5 114 5 1/2 YES 32 S-69 WEST SIDE 33K 5 1/4 5 5/g YES 33 B-69 WE.qT SIDE 33K 5 1/4 5 3/4 YES 34 S-69 WEST SIDE 33K 5 1/4 5 3/4 YES 35 S-69 WEST SIDE 33K 5 114 5 1/2 YES 36 S-69 WEST SIDE 33K 5 1/4 5 1/2 YES 37 S-6I WEST SIDE 33K 4 518 4 7/8 YES 38 B-32 WF.3T SIDE 33K 2 3/8 2 3/8 YES** _:quipment ID: Ram No: Pump No: Gauge No: Equipment Calibration Date: Comments: *SHORT, + LONG, POSSIBLE UNDER PULL; **REPULLED Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (I) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any o~er feature of similar subject maUer provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c :\wpwin\reports\D7429-161A-98\ST Revised April 22, 1998 Rone Engineers, Inc. ~734 Goodnight Lane i Tel. (972) 241-4 '~ ineers Dallas!Forl Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 3 OF 4 Report No: 3137-D7429-161A Sample Date: April 17, 1998 Client: Western Rim Services Report Date: April 22, 1998 Location: Building #41 Technician: Mike Fuller # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 S-32 WEST SIDE 33K 2 3/8 2 3/8 YES 40 S-61 SOUTH SIDE 33K 4 5/8 4 1/2 YES 41 B-61 SOUTH SIDE 33K 4 5/g 4 YES** 42 S-70 SOUTH SIDE 33K 5 3/g 5 3/4 YES 43 S-98 SOUTH SIDE 33K 7 5/8 $ YES 44 S-101 SOUTH SIDE 33K 7 7IS $ 1/16 YES 45 S-101 SOUTH SIDE 33K 7 '7/8 $ YES 46 B-75 SOUTH SIDE 33K 5 3/4 6 YES 47 S-102 SOUTH SIDE 33K 7 7/8 7 7/8 YES 48 S-102 SOUTH SIDE 33K 7 7/8 8 YES 49 S-102 SOUTH SIDE 33K 7 7/8 7 7/8 YES 50 B-76 SOUTH SIDE 33K 5 7/8 5 3/4 YES 51 S-98 SOUTH SIDE 33K 7 5/8 7 3/4 YES 52 S-98 SOUTH SIDE 33K 7 5/8 7 3/4 YES 53 S-98 SOUTH SIDE 33K 7 5/8 8 1/16 YES 54 S-98 SOUTH SIDE 33K 7 5/8 7 3/4 YES 55 S-101 SOUTH SIDE 33K 7 7/8 8 YES 56 15-74 SOUTH SIDE 33K 5 3/4 6 YES 57 S-101 SOUTH SIDE 33K 7 7/8 S YES ~-quipment ID: Ram No: Pump No: Gauge No: Equipment Calibration Date: Comments: *SHORT; **REVISED Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Darnron; C. D. Construction Consulting LIMrrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters nnd reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-161A-98\ST Revised April 22, 1998 Rone Engineers, Inc. ~.34 Goodnight Lane Tel. (972)241-4 RoneEnoineers Da,as/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT · Project: Mansion By The Lake Page 4 OF 4 Report No: 3137-D7429-161A Sample Date: April 17, 1998 Client: Western Rim Services Report Date: April 22, 1998 Location: Building//41 Technician: Mike Fuller # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (I) End (2) Elongations Tolerance $8 S-101 SOUTH SIDE 33K 7 7/8 8 3/4 59 S-101 SOUTH SIDE 33K 7 7/8 8 60 B-79 EAST SIDE 33K 6 1/8 7 1/$ 61 S-IS EAST SIDE 33K 1 2 62 S-27 EAST SIDE 33K 2 2 63 S-27 EAST SIDE 33K 2 2 64 B-27 EAST SIDE 33K 2 2 Equipment ID: Ram No: Pump No: Gauge No: Equipment Calibration Date: Comments: * + LONG, POSSIBLE UNDER PULL Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. Wc assume no responsibility for variation in quality (composition, appearnnce, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom the)' are addressed. c:\wpwin\reports\D7429-161A-98~ST Revised April 22, 1998