Loading...
Mansions Phase 1-LR 980421 (6) ~on,~ F_ngineer~. inc. :34 Gooclnio~nt Lane , Tel. (972) 241-4~. Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-143 Date of Observation 4/07/98 Report Date 04/21/98 To Western Rim Services Location BUILDING 38, NORTHWEST CORNER Contractor EDWARDS CONSTRUCTION Supplier LATTIMORE IPlant 7 J Truck755 Ticket 7049294 I I Time Sampled 9:50 Time Batched 9:35 Weather Condition CLEAR Concrete Temperature (°F) Ambient Temperature {°F) Mix Number 14 Mix Description 4.50 SACKS W/R Unit Weight Water Added 8 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6.5 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 79A 7 4/14 76000 2690 3000/28 DAYS B 28 4/05 C 28 4/05 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Mike Hedge; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, peHermance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our let/ers and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-143-98\ST April 21, 1998.,~"'~'~~