Mansions Phase 1-LR 980416 (5) Ro.~ En~jineers. Inc. 11~ Goodnight Lane Tel. (972) 241-4517~. Rone Enaineers
Dallas,'Fo~ Worth Da,as, Texas Metro (972) 263-155b
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-085 I Date of Observation 3/13/98 Report Date 04/16/98
I
To Western Rim Services
Location BUILDING #3, LOWER AND UPPER PART ON LEFT HAND SIDE
Contractor
Supplier LATTIMORE IPlant7 ITruck573 Ticket 7045193
Time Sampled 6:30 Time Batched 6:20 Weather Condition LT RAIN
Concrete Temperature (°F) 59 Ambient Temperature (°F) 52 Mix Number
Mix Description 6 SACKS W/R Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7 1/2
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
45A 7 3/20 106000 3250 3000/28 DAYS
B 28 4/10 143000 5060
C 28 4/10 140000 4950
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or an'/ other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom th~.,.~y_~re
addressed.
c:\wpwin\reports\D7429-085-ge~sT April 16, 1998 ~