Mansions Phase 1-LR 980416 (6) I~i~ J~t~§i.~l'~. I!~. '11.~-'2,4 C-,oodnigh~. Lane Tel. (972) 241-4517~. RoneEnaineers
Dallas/Foe, Wort~ Da~as. Texas Metro (972) 263-; 5:~ i
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-086 I Date of Observation 3/13/98 Report Date 04/16/98
I
To Western Rim Services
Location BUILDING 33, RIGHT LOWER SIDE
Contractor
Supplier LATTIMORE J Plant 7 J Truck 573 Ticket 7049205
I
I
Time Sampled 8:00 Time Batched 7:50 Weather Condition CLOUDY
Concrete Temperature (°F) 58 Ambient Temperature (°F) 52 Mix Number
Mix Description 5 SACKS W/R Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7.0
Concrete Cylinder Test(s)
J J J T°ta' L°ad I Compressive
Specimen Age Test Date
No. (Days) (lbs,) Strength (psi) Strength Required (psi)
46A 7 3/20 86000 3040 3000/28 DAYS
B 28 4/10 145000 5130
C 28 4/10 141000 4990
D H
Curing Method J Test Method Standard 6" x 12" I Engineer/Technician D. GODBEY
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
I
Signature: Mike Fuller, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin~reports\D7429-O86-98~ST April 16, 1998