Loading...
Mansions Phase 1-LR 980414 (10) Rone Engineers, Inc. 34 Goodnight Lane Tel. (972) 241-45, ineers Dallas.:Fon Wodn Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 1 of 4 Report No: 3137-D7429-147 Sample Date: April 9, 1998 Client: Western Rim Services Report Date: April 14, 1998 Location: CLUB HOUSE Technician: Tim Duke # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End 6) Elongations Tolerance I S WEST SIDE 33K 7800 1 3/4 2 B WEST SIDE 33K 7800 2 1/4 3 WE, ST SIDE 33K 7800 2 3/8 4 WEST SIDE 33K 7800 2 3/8 5 WEST SIDE 33K 7800 2 1/2 6 WEST SIDE 33K 7800 2 I/4 7 WEST SIDE 33K 7800 2 9/16 8 B WEST SIDE 33K 7800 3 1/2 9 WEST SIDE 33K 7800 5 10 WEST SIDE 33K 7800 4 11 WE.ST SIDE 33K 7800 4 1/2 12 WEST SIDE 33K 7800 4 13 SOUTH SIDE 33K 7800 2 3/4 14 B SOUTH SIDE 33K 7800 2 1/2 15 SOUTH SIDE 33K 7800 7 16 B SOUTH SIDE 33K 7800 6 3/4 17 SOUTH SIDE 33K 7800 7 18 SOUTH SIDE 33K 7800 7 1/4 19 SOUTH SIDE 33K 7800 6 1/4 I~.quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 1/05/98 Comments: Contractor did not have updated version of Club House plans for cable layout. Will update when Rone Engin~rs receives plans. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no respom'4bilily for variation in quality (composition, appearance, performance, err..) or an)' other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-147-98\ST ~ April 14, 1998 Rone Engineers, Inc. .34 Goodnight Lane Tel. (972) 241-45,. RoneEngineers Dallas/Fort Worln Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 2 of 4 Report No: 3137-D7429-147 Sample Date: April 9, 1998 Client: Western Rim Services Report Date: April 14, 1998 Location: CLUB HOUSE Technician: Tim Duke # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressur~ Elongations End (1) End (2) Elongations Tolerance 20 B SOUTH SIDE 33K 7800 6 3/8 21 SOUTH SIDE 33K 7800 7 118 22 SOUTH SIDE 33K 7800 7 1/2 ~ SOUTH SIDE 33K 7800 5 518 24 SOUTH SIDE 33K 7800 4 7/8 25 B SOUTH SIDE 33K 7800 5 26 SOUTH SIDE 33K 7800 5 1/2 27 SOUTH SIDE 33K 7800 5 318 28 SOUTH SIDE 33K 7800 4 3/4 29 SOUTH SIDE 33K 7800 2 30 SOUTH SIDE 33K 7800 5 1/4 31 sOUTH SIDE 33K 7800 2 5/8 32 SOUTH SIDE 33K 7800 3 3/4 33 B SOUTH SIDE 33K 7800 3 3/4 34 SOUTH SIDE 33K 7800 4 35 SOUTH SIDE 33K 7800 4 36 SOUTH SIDE 33K 7800 4 37 B SOUTH SIDE 33K 7800 4 38 SOUTH SIDE 33K 7800 4 1/4 ]~quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 1/05/98 Comments: Contractor did not have updated version of Club House plans fbr cable layout. Will update when Rone Engineers receives plans. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subj,'et matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-147-98\ST April 14, 1998 Rone Engineers, Inc. , .34 Goodnight Lane Tel. (972) 241-45,. RoneEngineers Dal[as/Forl Worl~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 3 of 4 Report No: 3137-D7429-147 Sample Date: April 9, 1998 Client: Western Rim Services Report Date: April 14, 1998 Location: CLUB HOUSE Technician: Tim Duke # Tendon Location .lack Force Gauge Rcquirad Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 SOUTH SIDE 33K 7800 3 7/8 40 SOUTH SIDE 33K 7800 3 314 41 B SOUTH SIDE 33K 7800 3 7/8 42 EAST SIDE 33K 7800 6 1/2 43 B EAST SIDE 33K 7800 6 5/8 44 EAST SIDE 33K 7800 6 314 45 EAST SIDE 33K 7800 6 3/4 46 EAST SIDE 33K 7800 6 3/4 47 EAST SIDE 33K 7800 6 518 48 EAST SIDE 33K 7800 7 49 EAST SIDE 33K 7800 7 1/g 50 EAST SIDE 33K 7800 7 I/8 51 EAST SIDE 33K 7800 7 1/8 52 EAST SIDE 33K 7800 1 1/2 53 EAST SIDE 33K 7800 7 1/8 54 EAST SIDE 33K 7800 2 1/2 55 EAST SIDE 33K 7800 7 1/2 56 EAST SIDE 33K 7800 3 57 EAST SIDE 33K 7800 7 .~quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 1/05/98 Comments: Contractor did not have updated version of Club Hous~ plans for cable layout. Will update when Rone Engineers receives plans. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry' Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Next'port Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMrrATIONS: The test results presented herein were prepared based upou the specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-147-98\ST April 14, 1998 Rone Engineers, Inc. _34 Goodnight Lane Tel. (972)241-45,, RoneEngineers Dallas/Fort Worlh Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 4 of 4 Report No: 3137-D7429-147 Sample Date: April 9, 1998 Client: Western Rim Services Report Date: April 14, 1998 Location: CLUB HOUSE Technician: Tim Duke # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 58 EAST SIDE 33K 7800 7 3/4 59 B EAST SIDE 33K 7800 7 1/4 60 NORTH SIDE 33K 7800 4 1/2 61 NORTH SIDE 33K 7800 4 3/8 62 NORTH SIDE 33K 7800 3 1/2 63 NORTH SIDE 33K 7800 1 3/4 .=quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 1/05/98 Comments: Contractor did not have updated version of Club House plans tbr cable layout. Will update when Rone Engineers receives plans. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (i) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon thc specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and mpLwts are for the exclusive use of the clients to whom they are addressed. c:~wpwin\reports\D7429-147-98\ST April 14, 1998