Mansions Phase 1-LR 980413 Rone Engineers, Inc. 111~' Goodnight Lane Tel. (972) 244-~597 "'~.
[3al~as,'Fo~ Wor~ Datlas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-074 I Date of Observation 3/04/98 Report Date 04/13/98
!
To Western Rim Services
Location PAVING, FIRE LANE, WEST SIDE AT SOUTHWEST CORNER OF BUILDING //39
Contractor
Supplier LATTIMORE I Plant 7 I Truck 573 Ticket 7047701
I
I
Time Saml01ed 12:00 Time Batched 11:19 Weather Condition PT CLOUDY
Concrete Temperature (°F) 64 Ambient Temperature (OFI 68 Mix Number 61
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.0
Concrete Cylinder Test(s)
[ i I T°tal L°ad JC°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
38A 7 3/11 62000 2190 3000/28 DAYS
B 28 4/01 99000 3500
C 28 4/01 93000 3290
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, {~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
{1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat results presented herein were prepared baaed upon the specific samples provided for testing. Wa assume no
responsibility for variation in quality (composition. appearance, performance, arc,) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports ara for the exclusive uae of the client~ to whom they are
addressed.
c:'~wpwin~reporta~D7429-O74-98~ST April 13, 1998
Rone Engineers, Inc. 11234 odnight Lane Tel. (972) 241-4517 ~ RoneEn_qineers
Dallas/For1 Worm Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-075 Date of Observation 3104/98 Report Date 04/13/98
To Western Rim Services
Location PAVING, FIRE LANE, EAST SIDE OF SOUTHEAST CORNER OF BUILDING //34
Contractor
Supplier LATTIMORE Plant 7 I Truck 458 Ticket 7047718
Time Sampled 2:45 Time Batched 2:09 Weather Condition PT CLOUDY
Concrete Temperature {°F) 64 Ambient Temperature (°F) 68 Mix Number 61
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.75
ENTRAINED AIR (%) 4.9
Concrete Cylinder Test(s)
I J IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
39A 7 3/11 78000 2760 3000/28 DAYS
B 28 4/01 110000 3890
C 28 4/01 107000 3780
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; Ciw of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc,) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports~,D7429-075-ea~ST April 13. 1998