Loading...
Mansions Phase 1-LR 980413 (4) Rone Engineers, Inc. _34 Goodnight Lane Tel. (972) 241-45.. RoneEn ineers Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-110 I Date of Observation 3/25198 Report Date 04/13/98 To Western Rim Services Location PARKING LOT BEHIND BUILDINGS //25, //26 AND//27 ON THE SOUTHWEST END, 10' EAST, 5' NORTH Contractor Supplier LATTIMORE Plant 3 I Truck 756 Ticket 3059614 Time Sampled 7:10 Time Batched 7:00 Weather Condition PT CLOUDY Concrete Temperature (°F) 68 Ambient Temperature (°F} 70 Mix Number 38 Mix Description 5.00 SACKS W/R AIR Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 Concrete Cylinder Test(s) Specimen Age r Test Date I Total Load J Compress,va No. (Days) {lbs.) Strength (psi) Strength Required (psi) 61A 7 4/01 52000 1840 3000/28 DAYS B 28 4/22 C 28 4/22 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, ~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell {1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C, D, Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters end reports ere for the exclusive use of the clients to whom they era addressed. c:\wpwin~reports\D7429-110-98\ST April 13, 1998