Loading...
Mansions Phase 1-LR 980413 (5) Rone Engineers, Inc. 112.'~"-~.~ooclnigl3t Lane Tel. (972) 24~-4~7 Rone Engineers Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-073 I Date of Observation 3/04/98 Report Date 04/13/98 To Western Rim Services Location PAVING, FIRE LANE, SOUTH SIDE AT SOUTHEAST CORNER OF BUILDING //39 Contractor Supplier LATTIMORE IPlant3 ITruck756 Ticket 3058416 Time Sampled 10:10 Time Batched 9:22 Weather Condition PT CLOUDY Concrete Temperature (°F) 62 Ambient Temperature (°F) 60 Mix Number 61 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4.5 ENTRAINED AIR (%) 4.5 Concrete Cylinder Test(s) No. (Days) Test Date (lbs.) Strength (psi) Strength Required (13si) 37A 7 3/11 90000 3180 3000/28 DAYS B 28 4/01 114000 4030 C 28 4/01 114000 4030 D H ASTM C 31 ASTM C 39/ Area 28.27 SCl. in. Signature: Kevin Tucker,~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The tea: results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc. I or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports~D742S-073-gS\ST April 13. 1998 Rone Engineers, Inc. 112 ,~oodnight Lane Tel. (972) 241-4517 ,"~ Rone ineers Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-072 I Date of Observation 3/'04198 Report Date 04/13/98 To Western Rim Services Location PAVING, FIRE LANE, EAST SIDE AT NORTHEAST CORNER OF BUILDING #39 Contractor Supplier LATTIMORE I Plant 7 I Truck 573 Ticket 7047675 Time Sampled 9:00 Time Batched 7:41 Weather Condition CLOUDY Concrete Temperature (°F) 64 Ambient Temperature (°F) 56 Mix Number 61 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4.5 ENTRAINED AIR (%) 4.8 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days} (lbs.) Strength (psi) Strength Required (psi) 36A 7 3/11 70000 2480 3000/28 DAYS B 28 4/01 100000 3540 C 28 4/01 114000 4030 D H Curing Method J TestMethod I Standard 6" x12" I Engineer/-I'echnicianG. BEALL ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, ~'~ Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell {1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The tact results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, perfon~snce, etc.} or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they ara addressed. c:\wpwin~reports\D7429-O72-98\ST April 13, 1998