Mansions Phase 1-LR 980413 (7) i Rone Engineers, Inc. ', _34 Goodnight Lane Tel. (972) 241-45,. RoneEn
Dal~as."Fo~ Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-111 Date of Observation 3/25/98 Report Date 04/13/98
To Western Rim Services
Location PARKING LOT NEXT TO BUILDING //26, SOUTHEAST END, 10' WEST, 2' NORTH
Contractor
Supplier LATrlMORE Plant 3 I Truck 456 Ticket 3059624
I
Time Sampled 10:20 Time Batched 10:10 Weather Condition CLEAR
Concrete Temperature {°F) 72 Ambient Temperature (°F) 70 Mix Number 38
Mix Description 5.00 SACKS W/R AIR Unit Weight Water Added 20 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP {in.) 5 1/2
Concrete Cylinder Test(s)
Specimen Age Test Date
No. {Days) (lbs.) Strength (psi) Strength Required (psi)
62A 7 4/01 59000 2090 3000/28 DAYS
B 28 4/22
C 28 4/22
D H'
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Mike Fuller, ~1~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The te~t results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided by
per~ons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:~wpwin\reports~D7429-111 -gS\ST April 13. 1998