Mansions Phase 1-LR 980408 Rone Engineers, Inc. ,. z34 Goodnight Lane Tel. (972) 241-453 / RoneEn ineers
Dallas!For1 Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-061 Date of Observation 3/02/98 Report Date 04/08/98
To Western Rim Services
Location FIRE LANE, SOUTH OF APARTMENT #13
Contractor
Supplier LATTIMORE IPlant7 ITruck757 Ticket 7047537
Time Sampled 10:38 Time matched 12:00 Weather Condition CLEAR
Concrete Temperature (°F) 60 Ambient Temperature (°F) 52 Mix Number 38
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.5
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) {lbs.) Strength (psi) Strength Required (psi)
28A 7 3/09 1 01000 3570 3000/28 DAYS
B 28 3/30 147000 5200
C 28 3/30 1 40000 4950
D H
Curing Method I Test Method Standard 6" x 12" I Engineer/Technician G. BEALL
ASTM C 31 I ASTM C 39 Area 28.27 sq. in.
I
Signature: Kevin Tucker, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D, Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for te~ting. We assume no
responsibility for variation in quality Icomposition, appearance, performance, etc.} or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they ere
addressed.
c:\wpwin\reports\D7429-061-98\ST April 8, 1998 ~