Mansions Phase 1-LR 980402 Rone Engineers, Inc. ,, 234 Goodnight Lane Tel. (972)241-451/ RoneEngineers Dallas/Fort Worlt~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 1 of 4 Report No: 3137-D7429-099 Sample Date: March 20, 1998 Client: Western Rim Services Report Date: April 2, 1998 Location: Building//3 Technician: Tim Duke # Tendon Looafion ]ack Forte Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) F. ad (2) Elongations Tolerance I B-29 WEST SIDE 33K 7800 2 115 2 114 YES 2 S-29 WEST SIDE 33K 7g00 2 l/g 2 l/g YES 3 S=48 WEST SIDE 33K 7800 3 5/8 3 I/2 YES 4 B-30 WF. ST SIDE 33K 7800 2 2/8 2 3/16 YES 5 B-30 WEST SIDE 33K 7800 2 2/8 2 1/4 YES 6 B-30 WF, ST SIDE 33K 7800 2 2/8 2 1/4 YES 7 B-30 WEST SIDE 33K 7800 2 2/8 2 1/8 YES 8 B-57 WEST SIDE 33K 7800 4 3/8 4 !/2 YES 9 5-57 ~ SIDE 33K 7800 4 3/8 4 1/4 YES 10 B-78 W~ST SIDE 33K 7800 6 5 3/8 YES 11 S-63 SOUTH SIDE 33K 7800 4 7/8 5 1/4 YES 12 S-62 SOUTH SIDE 33K 7800 4 314 5 YES 13 B-62 SOUTH SIDE 33K 7800 4 3/4 4 5/8 YES 14 S--62 SOUTH SIDE 33K 7800 4 3/4 4 3/4 YES 15 S-62 SOUTH SIDE 33K 7800 4 3/4 4 3/4 YES 16 S-65 SOUTH SIDE 33K 7800 5 5 YES 17 B-65 SOUTH SIDE 33K 7800 5 5 YES 15 S-65 SOUTH SIDE 33K 7800 5 5 YES 19 S-61 SOUTH SIDE 33K 7800 4 5/8 4 1/2 YES cquipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City ot Coppeli (1) Mr. Tony Martin; Ney, port Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results pmser,~ed herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in qualily (cc,..mpoaition, appearance, performance, ete.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-099-97\gT April 2, 1998 ~ Rone Engineers, Inc. . . 234 Goodnight Lane Tel. (972) 241-45'i / Rone ineers Dallas/Fort Worttn Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 2 of 4 Report No: 3137-D7429-099 Sample Date: March 20, 1998 Client: Western Rim Services Report Date: April 2, 1998 Location: Building//3 Technician: Tim Duke # Tendon Location lack For:e Gaug~ Requirad Elongations Elongations Tolal Within No. (Kips) Pre~sure Elongations End (1) End (2) Elongations Tolerance 20 S-61 SOUTH SIDE 33K 7800 4 5/8 4 1/2 YF3 21 B-64 SOUTH SIDE 33K 7800 4 7/8 4 7/8 YF.,5 22 S-64 SOUTH SIDE 33K 7800 4 7/8 5 YES 23 S-64 SOUTH SIDE 33K 7800 4 7/8 4 7/8 YES 24 S-62 SOUTH SIDE 33K 7800 4 3/4 4 7/8 YF.~ 25 $-64 SOUTH SIDI:- 33K 7800 4 7/8 4 7/8 YES 26 B-64 SOUTH SIDE 33K 7800 4 7/8 5 1/8 YES 27 S--62 SOUTH SIDE. 33K 7800 4 3/4 4 7/8 YES 28 $--62 SOUTH SIDE 33K 7800 4 3/4 4 7/8 YES 29 B-69 Sou'rH SIDE 33K 7800 5 1/4 5 1/4 YE3 30 S-69 SOUTH SIDE 33K 7800 5 1/4 5 1/8 31 S-69 SOUTH SIDE. 33K 7800 5 1/4 5 3/8 YF_.3 32 $-69 SOUTH $ID£ 33K 7800 5 1/4 5 3/8 YES 33 B-69 SOUTH SIDI~ 33K 7800 5 1/4 5 1/2 YES 34 S-69 SOUTH SIDE 33K 7800 5 i/4 5 1/2 YES 35 $-69 SOUTH $IDI:. 33K 7800 5 I/4 5 1/2 YES 36 ,%-69 SOUTH SIDE. 33K 7800 5 i/4 5 1/2 YES 37 S-61 SOUTH SIDE 33K 7800 4 5/8 4 I/2 YES 38 B-32 SOUTH SIDE 33K 7800 2 3/8 2 3/8 YES 3,quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (I) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results prcser!ted herein were prepared based upon the specific samples provided for testing. Wc assume no responsibility for variation in quality (composition, appearance, performance, ¢Ic.) or any other feature of similar subject matter provided by persons or conditions over which wc have no control. Our letters and repons are for thc exclusive use of the ellen,s to whom they are addressed. c:\wpwin\repons\D7429-099-97~T April 2, 1998 Rone Engineers, Inc. , . 234 Goodnight Lane Tel. (972) 241-45'1 / ineers Dallas/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 3 of 4 Report No: 3137-D7429-099 Sample Date: March 20, 1998 Client: Western Rim Services Report Date: April 2, 1998 Location: Building//3 Technician: Tim Duke # Tendon Location .lack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 39 S-32 SOUTH SIDE 33K 7800 2 3/8 2 1/4 YES 40 S-61 EAST SIDE 33K 7800 4 518 4 7/8 YES 41 B-61 EAST SIDE 33K 7800 4 5/8 4 5/8 YES 42 S-70 EAST SIDE 33K 7800 5 3/8 5 1/2 YES 43 S-98 EAST SIDE 33K 7800 7 5/8 7 1/2 YE3 44 S-101 EAST SIDE 33K 7800 7 7/8 7 7/8 YES 45 S-101 EAST SIDE 33K 7800 7 7/8 8 YES 46 B-75 EAST SIDE 33K 7800 5 3/4 5 3/4 YF-3 47 S-102 EAST SIDE 33K 7800 7 7/8 8 1/8 YES 48 S-102 EAST SIDE 33K 7800 7 7/8 8 YES 49 S-102 EAST SIDE 33K 7800 7 7/8 8 Y'ES 50 B-76 EAST SIDE 33K 7800 5 7/8 6 YES 51 S-98 EAST SIDE 33K 7800 7 518 7 3/4 YES 52 S-98 EAST SIDE 33K 7800 7 518 7 3/4 YES 53 S-98 EAST SIDE 33K 7800 7 5/8 7 1/2 YES 54 S-98 EAST SIDE 33K 7800 7 518 8 YES 55 S-101 EAST SIDE 33K 7800 7 7/8 7 3/4 YES 56 B-74 EAST SIDE 33K 7800 5 3/4 6 YES 57 S-101 EAST SIDE 33K 7800 7 7/8 7 3/4 YES Equipment It): Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (I) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results preset, led herein were prepared based upon the specific samples provided for testing. We assumc no responsibility for variation in qualily (c¢.mposition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our leuers and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reporlz\D7429-099-97\ST April 2, 1998 Dal~as/Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 4 of 4 Report No: 3137-D7429-099 Sample Date: March 20, 1998 Client: Western Rim Services Report Date: April 2, 1998 Location: Building//3 Technician: Tim Duke # Tendon Location Jack For=e Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 58 S-101 EAST SIDE 33K 7800 7 7/8 $ YES 59 S-101 EAST SIDE 33K 7800 7 7/8 $ YES 60 B-79 EAST SIDE 33K 7800 6 1/g 6 1/4 YES 61 S-15 EA..ST SIDE 33K 7800 I 15/16 YES 62 S-27 EAST SIDE 33K ' 7800 2 2 YES 63 S-27 EAST SIDE 33K 7500 2 2 YES 64 B-27 EAST SIDE 33K 7800 2 2 YES :quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon Ihe specific samples provided for testing. We assume no responsibility for variation in quality (composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we ha.re no comrol. Our letters and reports are for the exclusive uae of the clients to whom they are addressed. c:\wpwin\reports\D7429-099-97~ST April 2, 1998