Mansions Phase 1-LR 980402 (03) : Rone Engineers, Inc. 1,/34 Goodnight Lane Tel. (972) 241-45',. RoneEn ineers
Dallas/Fort Worth Dallas, lexas Metro (972) 2t53-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-058 I Date of Observation 3/02198 Report Date 04/02198
I
To Western Rim Services
Location FIRE LANE BETWEEN APARTMENT 34 AND 35
Contractor
Supplier LATTIMORE Plant 3 I Truck 782 Ticket 3058202
I
Time Sampled 7:20 Time Batched 6:29 Weather Condition CLEAR
Concrete Temperature (°F) 52 Ambient Temperature (°F) 33 Mix Number 61
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP {in.) 6.0
ENTRAINED AIR (%) 4.4
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
25A 7 3/09 58000 1980 3000/28 DAYS
B 28 3/30 73000 2580®
C 28 3/30 82000 2900®
D 56 4/27
Curing Method I Test Method/ Standard 6" x 12" I Engineer/Technician G. BEALL
Area sq.
ASTM C 3~v~. I ASTM C 39¢::~ 28.27 in.
I
Signature:[ Kevin Tucker, /~' Supervisor, CMT
Remarks and/or Distribution
'DIDN'T REACH REQUIRED STRENGTH, WILL TEST HOLD CYLINDER AT 56 DAY BREAK
Distribution: (1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C, D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. Wa assume no
responsibility for variation in quality (composition. appearance, peHormence, etc.) or any other feature of siroilar subject matter provided by
per~ons or conditions over which we have no control. Our letters and reports era for the exclusive usa of the clients to whom they ere
addressed.
c:\wpwin\reports\D7429-OSS-98\ST April 2. 1998