Mansions Phase 1-LR 980402 (06) Rone Engineers, Inc. 11/34 Goodnight Lane Tel. (972) 241-451. RoneEngineers
Dallas:Fort Worth Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-062 I Date of Observation 3/02/98 Report Date 04/02198
To Western Rim Services
Location FIRE LANE, NORTHEAST CORNER OF APARTMENT //11
Contractor
Supplier LATTIMORE Plant 7 I Truck 576 Ticket 7047534
I
Time Sampled 12:55 Time Batched 1:40 Weather Condition CLEAR
Concrete Temperature (°F) 66 Ambient Temperature (°F) 52 Mix Number 38
Mix Description Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.25
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required {psi)
29A 7 3/09 87000 3080 3000/28 DAYS
B 28 3/30 116000 4100
C 28 3/30 121000 4280
D H
Curing Method I Test Method Standard 6" x 12" I Engineer/Technician G. BEALL
in.
Area
I
sq.
ASTM C 39(,~
ASTM C 3il I 28.27
Signature:~ I<,evin Tucker, ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality Icornposition. appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:~wpwin\reports\D7429-062-98\ST April 2, 1998