Mansions Phase 1-LR 980402 (08) Rone Engineers. Inc. Ii ~34 Goodnight Lane Tel. (972)241-45', RoneEngineers
Dal,as/Forl Worth Dallas. Texas Metro (972) 263-1555
; 75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-064 I Date of Observation 3~02/98 Report Date 04/02/98
To Western Rim Services
Location FIRE LANE, SOUTHWEST CORNER, APARTMENT #11
Contractor
Supplier LATTIMORE Plant 7 I Truck 615 Ticket 6067310
I
Time Sampled 4:50 Time Batched 3:58 Weather Condition CLEAR
Concrete Temperature (°F) 64 Ambient Temperature (°F) 56 Mix Number 38
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.75
Concrete Cylinder Test(s)
Specimen Age Test Date
No. {Days) (lbs.) Strength {psi) Strength Required {psi)
3 lA 7 3/09 63000 2230 3000/28 DAYS
B 28 3/30 88000 3110
C 28 3/30 92000 3250
D H
Signature.~ Kevin Tucker, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided by
persons or conditions over which wa have no control. Our letters and reports are for the exclusive use of the clients to whom they ere
addressed.
c:\wpwin\reports\D7429-O64-98\ST April 2, 1998