Mansions Phase 1-LR 980402 (17) Rone Engineers, Inc. , ~34 Goodnight Lane Tel. (972)241-45,. RoneEn_clineers
Dallas/For[, Worn Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-105 I Date of Observation 3/24/98 Report Date 04/02/98
To Western Rim Services
Location BUILDING //29, SLAB, THE NORTHEAST CORNER, 5' WEST
Contractor EDWARDS CONSTRUCTION
Supplier LATTIMORE I Plant 6 I Truck 803 Ticket 6068683
I
I
Time Sampled 7:20 Time Batched 7:00 Weather Condition CLEAR
Concrete Temperature (°F) 67 Ambient Temperature (°F) 62 Mix Number 14
Mix Description 4.50 SACKS W/R Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.0
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
57A 7 3/31 56000 1 980 3000/28 DAYS
B 28 4/21
C 28 4/21
D H
Curing Method I Test Method I Standard 6" x 12"I Engineer/Technician D.
GODBEY
ASTMC31 I ASTMC39 I Area 28.27 sq. in. I
Signature: ~-Mike Fuller,~Supervisor, CUT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat reauits preeanted herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
pereons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:~wpwin~reports~D7429-10B-98~,ST April 2. 1998