Loading...
Mansions Phase 1-LR 980401 (4) Rone Engineers, Inc. ~ '~ _34 Goodnight Lane Tel. (972) 241-45. ineers Dal,as/Foa Wort~ : Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 1 of 4 Report No: 3137-D7429-113 Sample Date: March 25, 1998 Client: Western Rim Services Report Date: April 1, 1998 Location: Building//45 Technician: Tim Duke # Tendon Location Jack Fome Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (1) End (2) Elongations Tolerance 1 B-29 NORTH SIDE 33K 7800 2 1/$ 2 YES 2 S-29 NORTH SIDE 33K 7800 2 1/8 *See Note *See Note 3 S-48 NORTH SIDE 33K 7800 3 518 3 3/8 YES 4 1~-30 NORTH SIDE 33K 7800 2 2/8 2 1/4 YES 5 B-30 NORTH SIDE 33K 7800 2 2/8 2 1/8 YES 6 B-30 NORTH SIDE 33K 7800 2 2/8 2 3/16 YES 7 B-30 NORTH SIDE 33K 7800 2 2/8 2 1/8 YES 8 B-57 NORTH SIDE 33K 7800 4 3/8 4 9/16 YES 9 S-57 NORTH SIDE 33K 7800 4 3/8 4 !/4 YES 10 B-78 NORTH SIDE 33K 7800 6 5 5/8 YES ll S-63 WEST SIDE 33K 7800 4 718 4 1/2 YES 12 S-62 WEST SIDE 33K 7800 4 3/4 4 3/4 YES 13 B-62 WEST SIDE 33K 7800 4 3/4 4 '//8 YES 14 S-62 WEST SIDE 33K 7800 4 3/4 5 YES 15 S-62 WEST SIDE 33K 7800 4 3/4 4 11/16 YES 16 S-65 WEST SIDE 33K 7800 5 5 YES 17 B-65 WEST SIDE 33K 7800 5 4 7/8 YES I$ S-65 WEST SIDE 33K 7800 5 4 15/16 YES 19 S-61 WEST SIDE 33K 7800 4 5/8 4 7/8 YES ~quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 ; Comments: *CABLE//2, S-29, IS MISSING Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (I) Mr. Doyle Damron; C. Di Construction Consulting LIMITATIONS: Thc test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of thc clients to whom they are addressed. c:\wpwin\reports~D7429-113-98~ST ! April 1, 1998 ~ Rone Engineers. Inc. 1. _34 Goodnight Lane Tel. (972) 241-45. RoneEngineers Dallas/Fort Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 2 of 4 Report No: 3137-D7429-113 Sample Date: March 25, 1998 Client: Western Rim Services Report Date: April 1, 1998 Location: Building #45 Technician: Tim Duke # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations End (i) End (2) Elongations Tol.'mnc¢ 20 S-61 WF. ST SIDE 33K 7800 4 518 4 1/2 YES 21 B-64 WEST SIDE 33K 7800 4 7/8 4 13/16 YES 22 S-64 W'EST SIDE 33K 7800 4 7/8 4 7/8 YES 23 S-64 WF3T SIDE 33K 7800 4 7/8 4 5/8 YES 24 S-62 V~.ST SIDE 33K 7800 4 314 4 5/8 YES 25 S-64 WE. ST SIDE 33K 7800 4 718 4 7/8 YES 26 B-64 V~r._.ST SIDE 33K 7800 4 7/8 5 1/]6 YES 27 S-62 WEST SIDE 33K 7800 4 3/4 4 5/8 YES 28 S-62 WEST SIDE 33K 7800 4 3/4 4 9/16 YES 29 B-69 WEST SIDE 33K 7800 5 1/4 5 I/8 YES 30 S-69 WEST SIDE 33K 7800 5 I/4 4 3/4 YES 31 S-69 WEST SIDE 33K 7800 5 I/4 5 YES 32 S-69 WEST SIDE 33K 7800 5 1/4 5 1/2 YES 33 B-69 WEST SIDE 33K 7800 5 I/4 5 7/16 YES 34 S-69 WEST SIDE 33K 7800 5 I/4 4 7/8 YES 35 S-69 WEST SIDE 33K 7800 5 1/4 4 7/8 YES 36 S-69 WEST SIDE 33K 7800 5 1/4 5 YES 37 $-61 WEST SIDE 33K 7800 4 5/8 4 7/16 YES 38 B-32 V~c_,ST SIDE 33K 7800 2 3/8 2 7/16 YES Equipment It): Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMTrATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-113-98\ST April 1, 1998 Rone Engineers, Inc. 1._34 Goodnight Lane Tel. (972) 241-45', RoneEngineers Dallas/Fod Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 3 of 4 Report No: 3137-D7429-113 Sample Date: March 25, 1998 Client: Western Rim Services Report Date: April 1, 1998 Location: Building//45 Technician: Tim Duke # Tendon Location .]ack Force Gauge Required Elongations Elongations Total Wilhin No. (Kips) Pressure Elongations End (l) End (2) Elongations Tolerance 39 S-32 WE&'T SIDE 33K 7800 2 3/8 2 1/8 YES 40 S-61 SOUTH SIDE 33K 7800 4 518 5 YES 41 B-61 SOUTH SIDE 33K 7800 4 5/8 4 3/8 YES 42 S-70 SOUTH SIDE 33K 7800 5 3/8 5 1/2 YES 43 S-98 SOUTH SIDE 33K 7800 7 5/8 7 11/l 6 YES 44 S-10I SOUTH SIDE 33K 7800 7 7/8 7 3/4 YES 45 S-101 SOUTH SIDE 33K 7800 7 7/8 *See Not~ NO 46 B--?5 SOI. Y'I'I-I SIDE 33K 7800 5 314 5 7/8 'YES 47 S~102 SOUTH SIDE 33K 7800 7 718 7 7/8 *See Not~ 48 S-102 SOUTH SIDE 33K 7800 7 7/8 8 1/8 YES 49 S-102 SOUTH SIDE 33K 7800 7 7/8 7 5/8 YES 50 B-76 SOUTH SIDE 33K 7800 5 7/8 6 1/8 YES 51 S-98 SOUTH SIDE 33K 7800 7 5/8 7 9/16 YES 52 S-98 SOUTH SIDE 33K 7800 7 5/8 7 3/4 YES 53 S-98 SOUTH SIDE 33K 7800 7 5/8 8 1/8 YES 54 S-98 SOUTH SIDE 33K 7800 7 5/8 7 3/4 YES 55 S-101 SOUTH SIDE 33K 7800 7 7/8 7 11/16 YES 56 B-74 SOUTH SIDE 33K 7800 5 3/4 5 9/16 YES 57 S-101 SOUTH SIDE 33K 7800 7 7/8 7 1/2 *See Note .'"quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: *Cable//57, S-101, was under pulled. After the repair, the dead end is now approximately lg" into slab from the concrete edge. Total elongation is the new adjusted measure. *Cable t/45, S-101, is missing, plus, cable 1/47, S-102, was moved 30" the West and is not in the Grade Beam as indicated on the Plans. Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (I) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented heroin were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subjecl matter provided by persons or conditions over which we have no conlrol. Our letters and reports arc for the exclusive use of the clients to whom they are addressed. c:gwpwin\repons\D7429-113-98\ST April I, 1998 Rone Engineers. Inc. 1 ,_34 Goodnight Lane Tel. (972) 241-45'1. ineers Dallas/Foal Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 ELONGATION REPORT Project: Mansion By The Lake Page 4 of 4 Report No: 3137-D7429-113 Sample Date: March 25, 1998 Client: Western Rim Services Report Date: April 1, 1998 Location: Building #45 Technician: Tim Duke # Tendon Location Jack Force Gauge Required Elongations Elongations Total Within No. (Kips) Pressure Elongations F. ad (I) End (2) Elongations Tolerance 58 S-101 SOUTH SIDE 33K 7800 7 7/8 7 3/4 YES 59 S-101 SOUTH SIDE 33K 7800 7 7/8 8 3/8 YES 60 B-79 SOUTH SIDE 33K 7800 6 1/8 6 1/8 YES 61 S-15 SOUTH SIDE 33K 7800 I I 1/16 YES 62 S-27 SOUTH SIDE 33K 7800 2 I 15/16 YES 63 S-27 SOUTH SIDE 33K 7800 2 I 7/8 YES 64 B-27 SOUTH SIDE 33K 7800 2 I 15/16 YES ~quipment ID: Ram No: 38077 Pump No: 380005 Gauge No: 38077 Equipment Calibration Date: 5/13/97 Comments: Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIIvnTATIONS: The test results presented herein were prepared baaed upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports arc for the exclusive use of the clients to whom they arc addressed. c:\wpwin\reports\D7429-113-98\ST April 1. 1998