Mansions Phase 1-LR 980326 (4) Rone Engineers, Inc. 1 ~-'- t Goodnight Lane Tel. (972 RoneEnqineers Dai~as~'For[ Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-085 I Date of Observation 3/13/98 Report Date 03/26/98 To Western Rim Services Location BUILDING //3, LOWER AND UPPER PART ON LEFT HAND SIDE Contractor Supplier LATTIMORE I Plant 7 I Truck 573 Ticket 7048193 I I Time Sampled 6:30 Time Batched 6:20 Weather Condition LT RAIN Concrete Temperature (°F) 59 Ambient Temperature (°F) 52 Mix Number Mix Description 5 SACKS W/R Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 7 1/2 Concrete Cylinder Test(s) I r T°ta' L°ad IC°mpressive Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 45A 7 3/20 106000 3250 3000/28 DAYS B 28 4/10 C 28 4/10 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Mike Fuller, Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell {1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The teat results presented herein were prepared baaed upon the specific samples provided for tearing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any ether feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin~reports\D7429-oes-98~ST March 26, 1998