Mansions Phase 1-LR 980316 Rone Engineers, Inc. 1'~ 234 Goodnight Lane Tel. (972) 241-45'1. RoneEn ineers
Dal~as.'Fo~ Wo~h Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-071 I Date of Observation 3/04/98 Report Date 03/16/98
I
To Western Rim Services
Location PAVING, FIRE LANE, EAST SIDE OF SOUTHEAST CORNER OF BUILDING #7
Contractor
Supplier LATTIMORE I Plant 3 I Truck 734 Ticket 3058396
I
I
Time Sampled 8:45 Time Batched 6:59 Weather Condition CLOUDY
Concrete Temperature (°F) 60 Ambient Temperature (°F) 54 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL S PECIFI CATI ON S
SLUMP (in.) 5.0
ENTRAINED AIR (%) 4.5
Concrete Cylinder Test(s)
SpecimenI Age I Test Date l Total Load l Compressive
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
35A 7 3/11 83000 2940 3000/28 DAYS
B 28 4/01
C 28 4/01
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The teat results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality Icompoeltion, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin\reports\D7429-O?l-98\ST March 16, 1998