Loading...
Mansions Phase 1-LR 980316 (3) Rone Engineers, Inc. 11234 Goodnight Lane Tel. (972) 241-451, RoneEn( ineers Dallas/For1 Worth Dallas. Texas : Metro (972) 263-1555 75229 Fax (972} 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-074 I Date of Observation 3104/98 Report Date 03/16/98 To Western Rim Services Location PAVING, FIRE LANE, WEST SIDE AT SOUTHWEST CORNER OF BUILDING //39 Contractor Supplier LATTIMORE IPlant7 ITruck673 Ticket 7047701 Time Sampled 12:00 Time Batched 11:19 Weather Condition PT CLOUDY Concrete Temperature (°F) 64 Ambient Temperature (°F) 68 Mix Number 61 Mix Description Unit Weight Water Added NONE 'Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 6.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 38A 7 3/11 62000 2190 3000/28 DAYS B 28 4/01 C 28 4/01 D H Curing Method I Test Method Standard 6" x 12" I Engineer/Technician G. BEALL ASTM C 31I ASTM C 39 Area 28.27 sq. in. I Signature: Kevin Tucker, Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The teat results presented heroin were prepared baaed upon the specific samples provided for tearing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reporta~D7429-O74-98\ST March 16, 1998