Loading...
Mansions Phase 1-LR 980313 Rone Engineers, Inc. 1'~'" t Goodnight Lane Tel. (972) 24!-45i~ RoneEn_qineers Da~la$,-'Foi!. Worn Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-028 I Date of Observation 2/10198 Report Date 03/13/98 I To Western Rim Services Location PAVEMENT AT MAIN ENTRANCE, 30' EAST AT CENTER LINE, SOUTH BOUND SIDE Contractor Supplier LATTIMORE I Plant 7 I Truck 757 Ticket 7046569 I I Time Sampled 8:00 Time Batched 7:22 Weather Condition CLEAR Concrete Temperature {°F) 60 Ambient Temperature (°F) 50 Mix Number Mix Description Unit Weight Water Added 5 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4.0 ENTRAINED AIR (%) 5.1 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 5A 7 2/17 78000 2760 3000/28 DAYS B 28 3/10 105000 3710 C 28 3/10 108000 3820 D H Curing Method I Test Method Standard 6" x 12" I Engineer/Technician R. CROWDER ASTM C 31 I ASTM C 39 Area 28.27 sq. in. I Signature: Kevin Tucker, ~- Supervisor, CMT Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic LIMITATIONS: The teat results presented heroin were prepared baaed upon the specific samples provided for tearing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addreaaed. c:\wpwin\reporta\D7429-O28-98\ST Mamh 13. 1998