Mansions Phase 1-LR 980313 (04) Rone Engineers, Inc. 1' t Goocln,ght Lane Tel. (972) 241-451-'''~ ineers
Dal~as,'For~ Worln Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-054 I Date of Observation 2/28/98 Report Date 03/13/98
I
To Western Rim Services
Location PAVING
Contractor
Supplier LATTIMORE Plant 7 I Truck 785 Ticket 7047441
I
Time Sampled 9:30 Time Batched 9:10 Weather Condition PT CLOUDY
Concrete Temperature (°F) 62 Ambient Temperature (°F) 45 Mix Number 61
Mix Description Unit Weight Water Added 10 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 7.0
ENTRAINED AIR (%) 4.7
Concrete Cylinder Test(s)
I I I m°ta''°ad Ic°mpress've
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
22A 7 3/07 72500 2560 3000/28 DAYS
B 28 3/28
C 28 3/28
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Kevin Tucker, Supervisor, CMT y
Signature:
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein were prepared baaed upon the specific samples provided for testing. Wa assume no
responsibility for variation in quality (composition, appearance, perfon~ance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for tho exclusive use of the clients to whom they are
addressed.