Mansions Phase 1-LR 980313 (08) Oa,,as/¢on Wo~h Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-059 Date of Observation 3102198 Report Date 03/13/98 To Western Rim Services Location FIRE LANE BETWEEN APARTMENTS 34 AND 43 Contractor Supplier LATTIMORE Plant 7 I Truck 761 Ticket 7047513 I Time Sampled 9:15 Time Batched 8:34 Weather Condition CLEAR Concrete Temperature (°F) 56 Ambient Temperature (°F) 40 Mix Number 61 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 26A 7 3/09 94000 3330 3000/28 DAYS B 28 3/30 C 28 3/3O D H Curing Method ] Test Method I Standard 6" x12" I Engineer/TechnicianG. BEALL ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, Supervisor, CMT ~' Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. Wa assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-O59-98~ST March 13, 1998