Mansions Phase 1-LR 980313 (11) Rone Engineers, Inc. 1 4 Goodnight Lane Tel. (972) 241-451 ineers
Dalias.-Forl Worlh Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-062 Date of Observation 3/02/98 Report Date 03/13/98
To Western Rim Services
Location FIRE LANE, NORTHEAST CORNER OF APARTMENT //11
Contractor
Supplier LATTIMORE I Plant 7 I Truck 576 Ticket 7047534
I
I
Time Sampled 12:55 Time Batched 1:40 Weather Condition CLEAR
Concrete Temperature (°F) 66 Ambient Temperature (°F) 52 Mix Number 38
Mix Description Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 5.25
Concrete Cylinder Test(s)
I I I T°tal L°ad IC°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
29A 7 3/09 87000 3080 3000/28 DAYS
B 28 3/30
C 28 3/30
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, Supervisor, CMT ~
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: The test results presented herein wore prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mat'tar provided by
persons or conditions over which we have. no control. Our letters and reports ara for the exclusive uae of the clients to whom they ara
addressed.
c:\wpwin\reports\D7429-O62-98~ST March 13, 1998