Loading...
Mansions Phase 1-LR 980313 (11) Rone Engineers, Inc. 1 4 Goodnight Lane Tel. (972) 241-451 ineers Dalias.-Forl Worlh Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-062 Date of Observation 3/02/98 Report Date 03/13/98 To Western Rim Services Location FIRE LANE, NORTHEAST CORNER OF APARTMENT //11 Contractor Supplier LATTIMORE I Plant 7 I Truck 576 Ticket 7047534 I I Time Sampled 12:55 Time Batched 1:40 Weather Condition CLEAR Concrete Temperature (°F) 66 Ambient Temperature (°F) 52 Mix Number 38 Mix Description Unit Weight Water Added 5 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.25 Concrete Cylinder Test(s) I I I T°tal L°ad IC°mpressive Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 29A 7 3/09 87000 3080 3000/28 DAYS B 28 3/30 C 28 3/30 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, Supervisor, CMT ~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein wore prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject mat'tar provided by persons or conditions over which we have. no control. Our letters and reports ara for the exclusive uae of the clients to whom they ara addressed. c:\wpwin\reports\D7429-O62-98~ST March 13, 1998