Loading...
Mansions Phase 1-LR 980313 (12) Rone Engineers, Inc. 11 t Goodnight Lane Tel. (972) 241-451: RoneEn_qineers Da~las.'Fort Wort~ Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-063 Date of Observation 3/02198 Report Date 03/13/98 To Western Rim Services Location FIRE LANE, SOUTHEAST CORNER APARTMENT //11 Contractor Supplier LATTIMORE Plant 7 I Truck 752 Ticket 7047567 Time Sampled 3:15 Time Batched 2:22 Weather Condition CLEAR Concrete Temperature (°F) 56 Ambient Temperature (°F) 68 Mix Number 38 Mix Description Unit Weight Water Added 5 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 ENTRAINED AIR (%) 4.5 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 30A 7 3/09 100000 3540 3000/28 DAYS B 28 3/30 C 28 3/30 D H ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, Supervisor, CMT ~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared baaed upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-O63-98\ST March 13, 1998