Loading...
Mansions Phase 1-LR 980313 (13) Rone Engineers, Inc. ! 1 ', 4 Goodnight Lane Tel. (972) 241-451. ineers Dallas,"For~ Worm Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-064 Date of Observation 3/02~98 Report Date 03/13/98 To Western Rim Services Location FIRE LANE, SOUTHWEST CORNER, APARTMENT //11 Contractor Supplier LATTIMORE I Plant 7 I Truck 615 Ticket 6067310 I I Time Sampled 4:50 Time Batched 3:58 Weather Condition CLEAR Concrete Temperature (OF) 64 Ambient Temperature (OF) 56 Mix Number 38 Mix Description Unit Weight Water Added 10 GALLONS Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4.75 Concrete Cylinder Test(s) I I IT°tal L°ad C°mpressive Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 3 lA 7 3/09 63000 2230 3000/28 DAYS B 28 3/30 C 28 3/30 D H Curing Method I TestMethod Standard 6" x12" I Engineer/TechnicianG. BEALL ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, Supervisor, CMT ~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test reaulta presented herein were prepared based upon the specific samplea provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin\reports\D7429-O64-98~ST March 13, 1998