Mansions Phase 1-LR 980313 (14) ,one Engineers, Inc. ~ --'4 Goodnigl~t Lane Tel. ( 72) 2~ ~-~,'- RoneEnnineers
Dallas,Fort Wortt~ Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-065 I Date of Observation 3/02/98 Report Date 03/13/98
I
To Western Rim Services
Location FIRE LANE, SOUTHWEST CORNER OF APARTMENT #10
Contractor
Supplier LATTIMORE I Plant 7 [Truck 761 Ticket 7047577
I
I
Time Sampled 5:25 Time Batched 3:25 Weather Condition CLEAR
Concrete Temperature (°F) 64 Ambient Temperature (°F) 52 Mix Number 38
Mix Description Unit Weight Water Added 20 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 4.5
Concrete Cylinder Test(s)
No. (Days} Test Date (lbs.} Strength (psi) Strength Required (psi)
32A 7 3/09 85000 3010 3000/28 DAYS
B 28 3/30
C 28 3/30
D H
Curing Method I TestMethod Standard 6" x12" I Engineer/TechnicianG. BEALL
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, Supervisor, CMT ~
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
(1) Mr. Doyle Damron; C. D. Construction Consulting
LIMITATIONS: l~e test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for vedation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive uae of the clients to whom they are
addressed.
c:\wpwin\reports\D7429-065-98\ST March 13, 1998