Mansions Phase 1-LR 980312 (2) Rone Engineers, Inc. 11 t Goodnight Lane : Tel. (972) 241-451- RoneEn ineers
Dal~as;Forl Worth Dallas, Texas Metro (972) 263-1555
75229 Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-024 I Date of Observation 2/04/98 Report Date 03/12/98
I
To Western Rim Services
Location WATER METER CAP, 5' WEST, 5' SOUTH FROM NORTHEAST CORNER OF METER CAP
Contractor
Supplier TXI I Plant 41 I Truck 460 Ticket 972982
I
Time Sampled 2:15 Time Batched 1:36 Weather Condition CLOUDY
Concrete Temperature (°F) 72 Ambient Temperature (°F) 60 Mix Number 8274
Mix Description 6 SACKS ADMIXIAIA Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.0
Concrete Cylinder Test(s)
I I IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
4A 7 2/11 99000 3500 3000/28 DAYS
B 28 3/04 130000 4600
C 28 3/04 131000 4630
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, Supervisor, CMT ~
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for tasting. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.