Loading...
Mansions Phase 1-LR 980312 (7) Rone Engineers, Inc. 11 ~ Goodnight Lane Tel. (972) 241-451; ineers Da~las,'Fort Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-047 I Date of Observation 2/25/98 Report Date 03/12/98 I To Western Rim Services Location PAVING, EAST SIDE PAD #44, 60' NORTH, 10' EAST FROM SOUTHEAST CORNER OF PAD SITE //44 Contractor Supplier LATTIMORE IPlant3 ITruck898 Ticket 3058008 Time Sampled 1:15 Time Botched 12:47 Weather Condition PT CLOUDY Concrete Temperature (°F) 75 Ambient Temperature (°F) 58 Mix Number 40 Mix Description Unit Weight Water Added NONE ' Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5 1/2 ENTRAINED AIR {%) 5.2 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) 18A 7 3/04 105000 3710 3500/28 DAYS B 28 3/25 C 28 3/25 D H ASTM C 31 ASTM C 39 Area 28.27 scl. in. Signature: Kevin Tucker, Supervisor, CMT f Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic (1) Mr. Doyle Damron; C. D. Construction Consulting LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, perfonaance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive usa of the clients to whom they are addressed. c:\wpwin\reports\D7429-O47-98~..ST March 12, 1998