Freeport NIP(7.6)-CS010906 97~ ~04 3547 7.~K
09/06/0~ ~4:46 CITY OF COPPELL ~ CITY OF COPPELL NO.3?D DOZ
MEMORANDUM
FROM THE
DEPARTMENT OF PUBLIC WORKS
....... II I Ill ~ .....
To: Larry Davis, Construction Inspector Engineering
From: Avery Rodgers, Streets Division Public Works
Date: September 6, 2001
RE: Walk-thru Freeport North 1~Taa,x~ ~o~
Inlet Boxes & RCP's
1. Grout top and bottom of box, grout joint~ in RCP and clean inlet box.
2. Inlet boxes inac~le due to broken lid.
3. Grout RCP at box, some Ramneck pushing out of joint.
4., Box inaccessible due to dirt and debris in and around box - grout box & grout RCP at
box.
Major Drainaee from Ponds
1. Barrels running east and west under Freeport full of mud.
2. Grout RCP at headwall at far north of pond.
3, **Put a ~rate on top of far north outflow.**
4. The 4 X 6 barrels at the far north end of outflow - a lot of the joints are not together.
~ CITY OF COPp£LL J:~B]_.]C WORKS DF.,ISARTM£~,