Mansions Phase 1-LR 980216 .one ~=ngineers, Inc. 1 4 Goodnigt3! Lane Tel. (97E) 241-45-. ineers
Dallas.-'Fort Worth Dallas. Texas Metro (972) 263-1555
75229 i Fax (972) 241-5174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-024 I Date of Observation 2/04/98 Report Date 02/16/98
I
To Western Rim Services
Location WATER METER CAP, 5' WEST, 5' SOUTH FROM NORTHEAST CORNER OF METER CAP
Contractor
Supplier TXI Plant 41 I Truck 460 Ticket 972982
I
Time Sampled 2:15 Time Batched 1:36 Weather Condition CLOUDY
Concrete Temperature (°F) 72 Ambient Temperature {°F) 60 Mix Number 8274
Mix Description 6 SACKS ADMIX/AIA Unit Weight Water Added 5 GALLONS
Physical Data
ACTUAL SPECIFICATIONS
SLUMP (in.) 6.0
Concrete Cylinder Test(s)
I I IT°tal L°ad C°mpressive
Specimen Age Test Date
No. (Days} (lbs.) Strength (psi) Strength Required (psi)
4A 7 2/11 99000 3.500 3000/28 DAYS
B 28 3/04
C 28 3/04
D H
ASTM C 31 ASTM C 39 Area 28.27 sq. in.
Signature: Kevin Tucker, ~ Supervisor, CMT
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
LIMITATIONS: The test results presented herein were prepared baaed upon the specific samples provided for testing. We assume no
responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and repo~a are for the exclusive uae of the clients to whom they ara
addressed.
c:\wpwin\raports\D7429-O24-98\ST February 16, 1998