Loading...
Mansions Phase 1-LR 980210 (3) none engineers, Inc. 112 Goodnight Lane Tel. (972) 241-4517 "" Iineers Dallas,-Forl Wort~. Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-019 r Date of Observation 1/30/98 Report Date 02/10/98 To Western Rim Services Location METER VALVE //1, EAST WALL, 4' FROM THE BOTTOM AT MIDDLE Contractor Supplier TXI Plant 41 I 71 lruck Ticket I Time Sampled 4:40 Time Batched 3:14 Weather Condition CLEAR Concrete Temperature (°F) 72 Ambient Temperature (°F) 68 Mix Number 8272 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 5.0 Concrete Cylinder Test(s) SpecimenI Age I Test Date l Total Load l Compressive No. (Days) (lbs.) Strength (psi) Strength Required (psi) 2A 7 2/06 86000 3040 3000/28 DAYS B 28 2/27 C 28 2/27 D H Curing Method I Test Method Standard 6" x 12" I Engineer/Technician K. MUSTAFA ASTM C 31I ASTM C 39 Area 28.27 sq. in. I Signature: Kevin Tucker, Supervisor, CMT,~~ Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.} or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive uae of the clients to whom they are addressed. c:\wpwin\reports\D7429-019-98~ST February 10, 1998