Loading...
Mansions Phase 1-LR 980205 Rone Engineers, Inc. : 11234 Goodnight Lane !i Tel. (972) 241-451, RoneEn. ineers Dallas.-'Fo~ Worth Dallas. Texas Metro (972) 263-1555 75229 Fax (972) 241-6174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-017 Date of Observation 1/29/98 Report Date 02/05/98 To Western Rim Services Location METER BOX //1 Contractor Supplier TXI Plant 41 I Truck 460 Ticket 968037 I Time Sampled 3:20 Time Batched 2:47 Weather Condition CLEAR Concrete Temperature (°F) 74 Ambient Temperature (°F) 71 Mix Number 8272 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP {in.) 4.75 ENTRAINED AIR (%) 5.0 Concrete Cylinder Test(s) Specimen Age Test Date No. (Days) (lbs.) Strength (psi) Strength Required (psi) lA 7 2/05 83000 2940 3000/28 DAYS B 28 2/26 128500 4530 C 28 2/26 130000 4800 D H Curing Method I Test Method Standard 6" x 12" I Engineer/Technician T. DUKE ASTM C 31I ASTM C 39 Area 28.27 sq. in. I Signature: Kevin Tucker, Supervisor, CMT ~ v Remarks and/or Distribution Distribution: (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality {composition. appearance, performance, etc.) or any other feature of similar subject matter provided by persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are addressed. c:\wpwin~reports~D7429-O17-98\ST February 5, 1998