Mansions Phase 1-LR 980205 Rone Engineers, Inc. : 11234 Goodnight Lane !i Tel. (972) 241-451, RoneEn. ineers
Dallas.-'Fo~ Worth Dallas. Texas Metro (972) 263-1555
75229 Fax (972) 241-6174
Concrete Cylinder Test Report
Project Mansion By The Lake Purchase Order
Number 3137-D7429-017 Date of Observation 1/29/98 Report Date 02/05/98
To Western Rim Services
Location METER BOX //1
Contractor
Supplier TXI Plant 41 I Truck 460 Ticket 968037
I
Time Sampled 3:20 Time Batched 2:47 Weather Condition CLEAR
Concrete Temperature (°F) 74 Ambient Temperature (°F) 71 Mix Number 8272
Mix Description Unit Weight Water Added NONE
Physical Data
ACTUAL SPECIFICATIONS
SLUMP {in.) 4.75
ENTRAINED AIR (%) 5.0
Concrete Cylinder Test(s)
Specimen Age Test Date
No. (Days) (lbs.) Strength (psi) Strength Required (psi)
lA 7 2/05 83000 2940 3000/28 DAYS
B 28 2/26 128500 4530
C 28 2/26 130000 4800
D H
Curing Method I Test Method Standard 6" x 12" I Engineer/Technician T. DUKE
ASTM C 31I ASTM C 39 Area 28.27 sq. in.
I
Signature: Kevin Tucker, Supervisor, CMT ~
v
Remarks and/or Distribution
Distribution:
(1) Mr. Richard E. Simmons; Western Rim Services
(1) Mr. Larry Davis; City of Coppell
(1) Mr. Lee Stone; City of Coppell
(1) Mr. Tony Martin; Newport Classic
LIMITATIONS: The test results presented herein were prepared based upon the specific samples provided for testing. We assume no
responsibility for variation in quality {composition. appearance, performance, etc.) or any other feature of similar subject matter provided by
persons or conditions over which we have no control. Our letters and reports are for the exclusive use of the clients to whom they are
addressed.
c:\wpwin~reports~D7429-O17-98\ST February 5, 1998