Loading...
Mansions Phase 1-LR 980205 (2) Rone Engineers, Inc. 11234 Goodnight Lane Tel. (972) 241-451, Rone ineers Dallas/For1 Worth Dallas, Texas Metro (972) 263-1555 75229 Fax (972) 241-5174 Concrete Cylinder Test Report Project Mansion By The Lake Purchase Order Number 3137-D7429-017 Date of Observation 1/29/98 Report Date 02/05/98 To Western Rim Services Location METER BOX #1 Contractor Supplier TX, IPlant41 ITruck460 Ticket 968037 Time Sampled 3:20 Time Batched 2:47 Weather Condition CLEAR Concrete Temperature {°F) 74 Ambient Temperature (°F) 71 Mix Number 8272 Mix Description Unit Weight Water Added NONE Physical Data ACTUAL SPECIFICATIONS SLUMP (in.) 4.75 ENTRAINED AIR (%) 5.0 Concrete Cylinder Test(s) ' No. (Days} Test Date {lbs.) Strength {psi) Strength Required (psi) lA 7 2/05 83000 2940 3000/28 DAYS B 28 2/26 C 28 2/26 D H Curing Method I Test Method I Standard6"xl2" I Engineer/TechnicianT. DUK:E ASTM C 31 ASTM C 39 Area 28.27 sq. in. Signature: Kevin Tucker, ~Supervisor, CMT Remarks and/or Distribution Distribution: : (1) Mr. Richard E. Simmons; Western Rim Services (1) Mr. Larry Davis; City of Coppell (1) Mr. Lee Stone; City of Coppell (1) Mr. Tony Martin; Newport Classic LIMITATIONS: The te~t results presented herein were prepared based upon the specific samples provided for testing. We assume no responsibility for variation in quality (composition, appearance, performance, etc.) or any other feature of similar aubject matter provided by pereons or conditions over which we have no control. Our letters and repo~s are for the exclusive use of the clients to whom they are addressed. c:\wpwin~reports\D7429-017-98\ST February 5, 1998