Loading...
Northlake 635(2)-LR 970528TECHNOLOGIES INC Max 2~ CLIENT: PROJECT: SERVICES: REPORT OF DRILLED PIER INSPECTION Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 COPPELL BUSINESS CENTER WRANGLER DR AND BELTLINE RD COPPELL TX PROJECT NO.: 0903 REPORT NO.: 1170t DATE OF SERVICE: AUTHORIZAT!ON: REPORT DATE: 5/: Perform Drilled Pier Inspection. REPORT OF INSPECTION On this date, a Maxim Technologies representative arrived c scheduled to perform a Drilled Pier Inspection. See attac] results of the inspection. Technician Time: 7:00am to ll:00am Page 1 of 2 Technician: Rusty Bowers Technician Report Distribution: (1} Uncoln Prc~pe~y Co. {11 8UTLER CONSTRUCTION INCORP. {1 } EIROCKb'TT-OAV~S..OR.AXE, INC. [1} THE CITY OF COPPEL/. {11 THE CITY OF COPPELL {11 O'BRIEN ASSOCIATES, INC. {1) A.E.C.C. 10gg DY im Tach. Southwestern Labs 75 Lone Star Dr. P.O. Box 224227 Dallas, Texas 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 605034 ~2 ~/19/97 zgoing !8/97 ~n site as Led report for ~ply ordy tO the ~emple t~lted and/o~ ~n~pected, end ate not :ndlcaUve of the qua~tme of ~lN~atenay TECHNOLOOiES INC LINCOLN PROPERTY COMPANY Project N~:0903605034 Service Date:05/19~97 2575 Lone Star Drive · P.O. Box 224227 · Daila (214) 631-2700 · Fax (214) 920-18: DRILLED pIER INSPECTION (STRAIGHT SHAVD Date Drilled:05/19/97***OBSERVATION OF DRILLED FOUNDATION s, Texag 75222 )1 Report N°: 117062 Page 2 of 2 CONSTRUCTION*** Pier identification J/4.5 Pier diameter(in}/'rype ~.7 i see note Depth of pier from surface(ft) see note Depth of bearing stratum from surface(ft) 31.3 see note Required penetration(ft) 6.0 see note Actual penetration(ft) · 6.4 see note Condition of bottom(wet/dry) i; see note Plumb within tolerance(yes/no} see note Casing diameter(in)/Length(ft) 25/15.0 see note //of bars/Reinforcing bar size(//) 6///6 see note Length of reinforcing steel(ft) 35.7 see note Time drilling was completed(am/pm) 9:40a see note Time concrete was placed(am/pm) 10:01am see note Depth of pier from top of concrete(ft) 36.2 , see note Elevation: Top of Pier (ft)/Bottom of Pier (ft) 98.0/61.8 , see note Elevation: Top of Bearing Stratum (ft) 68.3 I See note Bearing stratum (Description} Dark gray unw~athere(~ shale. NOTE: SEE REPORT # 116590 FOR COMPRESSIVE STRENGTH TEST SPECIMENS. · ADDITIONAL PENETRATION NOT REQUESTED UNLESS NOTED. · · ELEVATION BY OTHERS TIME: 7:00 A.M. TO 11:00 P.M. NOTE: Not drilled due to rain. Our lettem and reportl are for the exclu, iv® u~e of the client to whom they are addressed and shall not be reprod approval of the testing laboratory. The uee of our name rnu~ receive prior written approval of Maxim Technologi only to the sample tested and/or in~peoted and are not indicative of the quantity of apparently identicaJ or similar aced except in full without the ~, Inc. Lettem and raporta apply ~'oducta.