WA9302-LR 950828 (2)[EOTECHNICAL E GEE Consultants, Inc. EINViRONMENTAL 2540 Glenda Lane · Suite 108 · Dallas, Texas 75229 · (214) 620-9791 · Fax (214) 620-9794 REPORT OF CONCRETE MIX DESIGN Report Date: August 28, 1995 Date Concrete Placed: A1/gu. St 19, ].995 Standard 6"x12" Client: City of Coppell Area 28.27 Square Inches Project: 6.0 Million Gallon Water Storage Tank ConcreteReportNo.: 1 Contractor: Natgun Construction Project No.: 95-0196 Concrete Supplier and Plant: RediMix Concrete 12 1 Plant Location of Placement: GEE Consultants, Inc. Laboratory Confirmation Cylinders MATE R IAL S s .... / Ba~h Wts. Description (lbs./0.07S C.V) INSPECTION DATA Mix Number: Pier Mix #686 Time Sample Batched: 11:00 am Cement: 45.8 lb. Time Sampled: 11:15 am Sample Location: GEE Consultants, Inc. Fly Ash: -0-- Truck/Ticket No: N/,A Coarse Aggregate: 136.9 lb. Temperature: Intermediate Aggregate: -0- Ambient Range: 94°F Fine Aggregate: 86.1 lb. Concrete Range: 92°F Slump Range (inches): 7th'' Admixtures: Weather Conditions: Clear 1 C494A 1.35 oz. Time Started: N/A 2 C260 0.23 oz. Time Completed: N/A Added Water: 20.6 lb. Sample Air Content (%): 5t/~ % Total Cubic Yards Placed: 0.075 C.Y. Required Strength (Lbs./sq.in.): 5,000 specimen Measured Age Date Total Load Compressive Strength Remarks Number Slump (in.) (Days) Tested (Lbs.) (Lbs./Sq.ln.) CWT 1 7~ 3 08/22/95 78,180 2,770 Unit weight: 141.6 |bs/cu.ft. CWT 2 7~ 3 08/22/95 80,560 2,850 Note: weights batched as provided with no CWT 3 7~ 7 08/26/95 89,540 3,170 moisture or volume corrections made, as CWT 4 7~ 7 08/26/95 90,920 3,220 requested. CWT 5 7~ 28 09/16/95 CWT 6 7~ 28 09/16/95 Test Methods Utilized Fracture Regular ASTM C-31,C-39,C-143 (Unless Noted Otherwise) Cylinders Made By: D.S.FW.I. Remarks and/or Distribution: cc: Mr. Larry Davis - City of Coppell Mr. Bob Barbarisi, Jr. - Natgun Corporation Mr. Gary Hendficks - Shimek, Jacobs and Finklea Mr. Gary Herron - RediMix Concrete GEE Consultants, Inc. Reviewed by: C~'~j ~J' (~' All letters aM reports are for the exclusive use of the client to whom they are addressed and shall not be reproduced without the full approval of GEE Consultants, Inc. The use of our name must receive our prior written approval. Our letters and reports apply only to the sample tested and/or inspected and are not necessarily indicative of the quantities of apparently identical or similar products.