November 12, 1997
Joseph Reue
Washington & Associates
500 Grapevine Hwy., Suite 375
Hurst, TX 76054
RE: Mansion by the Lakes Phase 1
Construction Plans -
Dear Mr. Reue:
The City of Coppell has received and reviewed the referenced plans and has the following comments to offer:
1. Provide the radius of all driveways and internal curves. ('~,~,t,, o,~ s,~g'e'-/' 3)
2.~ Provide a note that no work will be done outside the phase line~s#~x/e,,.,
~. Provide a detail on how trees are to be protected during construction.&~a,,~ ~,~,' g,vee"-r
47 Indicate on the drainage area map future storm drainage system for Phase II,/s~wa~t o,,.~
5.'~ Drainage area F-1 appears to be large; should look at adding additional inlets.(//a~
6.TM Fire lanes should not be used for storm drainage capacities/c/'va'ttr r>,~x.t~vt,m) ..qooo-,eax~-r tot.4.)
7.'~ Provide detail on how the paving invert will transition at curb opening. Also, provide detail of erosion
protection at all curb openings. Should consider putting drainage into a pipe and discharge into
channel. ~1o~ o~u, ~n~-e-r ~)
8.~ Provide profile views of all storm drainage systems.(.,~tl~.,2~ o.a.~ ~',,4F~'r 4-.)
9.`/ The City of Coppell Subdivision ordinance requires 6" of lime stabilized subgrade underneath paving.
If you have an alternate pavement design submit a letter requesting a variance along with a cop>' of
geotechnical report. The City Engineer has allowed one additional inch of paving or increase of
strength of paving to 4000 psi all on 95 % compacted subgrade. ~'~'E'~' ,0~7',,~ove'o
t0f Are you proposing any 8' wide brick paver band for the driveways intersecting Coppell Road~5~'e'
11 .~ All fire hydrant locations to be approved by the Fire Marshal.(_~4~' A/~0~ 8~'e-.,~ x~o-~//,..~,
127 Label on the plans the existing sanitary sewer line on the north side of the development.~'-)
13./ The existing sanitary sewer line and manholes should be abandoned as per the City's standards.(E~o~J
14.''~ Make correction to the CiW of Coppell telephone number as indicated on the plans.
15.~ The 2 existing meters on Coppell Road a the northwest corner of the development should be abandoned
if they are not to be used.4~2:~oe-J
16.''~ All bores should be dry
17.~'rhe manholes on Line "A" at stations 15+51.66 and 17+90.73 need to be 5 foot diameter
manholes. ~t:,on~
There are various other minor comments throughout the plans. Once these comments have been addressed,
the marked up plans along with two revised sets of plans should be resubmitted to the City for review. If
any major changes occur please indicate on the plans. If you should have any questions concerning these
comments, please contact me at 304-3681.
Sil)/~relx · ·
....
Michael A. Martin, P.E.
Assistant City Engineer