Northlake 635(2)-LR 970519 (2)Maxi 25~ TECHNOLOGIES INC REPORT OF CONCRETE COMPRESSIVE STRENGTH CLIENT: Lincoln Property Co. 500 N. AKARD, SUITE 3300 ATTN: LARRY MOON Dallas, TX 75201 PROJECT: COPPELL BUSINESS CENTER WRANGLER DR AND BELTLINE RD COPPELL TX PAGE i OF 2 PROJECT NO.: 0903, REPORT NO.: 11655 DATE OF SERVICE: 5 AUTHORIZATION: C]' REPORT DATE: 5 / :] SERVICES: Test compressive strength specimens prepared in conjunctJ inspection. CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C173 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED 1 1 5/19/97 i 2 5/19/97 1 3 6/09/97 PROJECT DATA MIX DESIGN NUMBER: 933~ DATE OF PLACEMENT: 5/] TIME SAMPLED: 11: 18~ TEMPERATURE (DegF) - AIR: TRUCK NO: 136 MEASURED SLUMP (in.): 5 o AIR CONTENT(%): 1.5 LOCATION OF PLACEMENT: Panel #29, 10' from REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) {in.) (sq.in.) {lbs. force) {psi) ' FI 7 6.00 28.27 94050 3330 C( 7 6.00 28.27 94540 3340 C( 28 I 4 6/09/97 28 Technician: David King Technician Report Of Tests Continued On Page 2 ~ Tech. · Southwestern Labs '5 Lone Star Dr. · P.O. Box 224227 Dallas, Texae 75222 Telephone: (214) 631-2700 FAX: (214) 920-1891 ~05034 2 /12/97 arlie 9/97 on with concrete 2/97 BY: David King 2 CONCRETE: 70 TICKET NO: 376505 5 UNIT WEIGHT(pcf): N/A bottom IACTURE TYPE REMARKS Ou~ et1~,. ~ repor~ a~e f~r the exclusive uae of th~ cJient to w~ t~y ~ ~ ~1 ~t ~,m~ ~ ~c~t in f~l with~ t~ aoorovN of ~ t~i~ I~ T~ ~ of ~ n~ m~ rl~vl o~ wfl~en ~rovl. ~ ~em ~ repoKs 1001 LW apply o~y to t~'~mp~ t~ ~/o~ i~, ~ ~e n~ i~i~five of t~ q~iti~ of Ipp~ently id~ti~ or ~milM pr~. Lincoln Property Co. PROJECT NO. 0903605034 DATE OF SERVICE: 5/12/97 REPORT OF CONCRETE COMPRESSIVE STRENGTH (Continued) CONTRACTOR: BUTLER CONSTRUCTION CONCRETE SUPPLIER: PIONEER PLANT: 22 SPECIFICATION REQUIREMENTS STRENGTH: 3000psi @ 28 DAYS SLUMP: 5" METHOD OF TEST SAMPLING: ASTM C-172 MOLDING & CURING: ASTM C31 SLUMP: ASTM C143 TEMPERATURE: ASTM C1064 AIR CONTENT: ASTM C173 UNIT WEIGHT: N/A CAPPING/PADS: ASTM C617 TESTING: ASTM C39 CYLINDER MARKED DATE SET NO. TESTED PROJECT DATA MIX DESIGN NUMBER: 933~ DATE OF PLACEMENT: 5/.' TIME SAMPLED: 01: 00PM TEMPERATURE (DegF) - AIR: TRUCK NO: 120 MEASURED SLUMP (in.): 4. AIR CONTENT(%): 1.0 LOCATION OF PLACEMENT: Panel ~10, 2' from REPORT OF TESTS CONCRETE COMPRESSIVE STRENGTH - 6 X 12 CYLINDERS MAXIMUM COMPRESSIVE AGE DIAMETER AREA LOAD STRENGTH (days) (in.) (sq.in.) (lbs. force) (psi) F 2 I 5/19/97 7 2 2 5/19/97 7 2 3 6/09/97 28 2 4 6/09/97 28 6.00 28.27 81810 2890 CC 6.00 28.27 90190 3190 CC Technician: David King Technician Report Distribution: I~ ~,~no. ,.co,P. MAXIM TECI I1) BROCKE 'r'T-OAVIS-ORAKE INC. I) THE CITY OF COPPELL ' {1) THE CITY OF COPPELL {1) O'BRIEN ASSOCIATES. INC. full witheut the ~provai et' the testin~ laboratory. The uae ef eu~ name mu~t receive eur written ~l~prev~. Our let1 1001 LW REPORT NO. 116592 PAGE 2 OF 2 SET NO. 2 .2/97 BY: David King 5 CONCRETE: 70 TICKET NO: 376516 5 UNIT WEIGHT(pcf): N/A iACTURE TYPE REMARKS NE ~,-=.-.t,_____en, B. S. ~ject Manager d except in Ch.E.